Professional wireless fire detection with both smoke and heat sensing.
The EMS SmartCell Wireless Dual Smoke & Heat Detector provides flexible fire detection as part of an EMS SmartCell wireless fire alarm system. It can detect smoke, heat, or both, depending on how the system is configured.
The detector communicates wirelessly with the SmartCell control panel using secure bidirectional 868 MHz communication, allowing it to be individually identified and monitored by the system. It is quick to install and particularly useful where conventional wired fire alarm systems would be disruptive or expensive to install.
⚠️ Important — SmartCell control panel required
This product does NOT work as an individual standalone smoke alarm.
It must be purchased and installed as part of an EMS SmartCell system and programmed to a compatible SmartCell control panel.
If you are building a new SmartCell system, you will need the SmartCell Wireless Fire Control Panel as well as the required detectors and other system devices.
The manufacturer's installation instructions specifically state that the detector must be added/programmed to the control panel during commissioning.
This product should therefore not be purchased as a replacement for a conventional standalone domestic smoke alarm.
Key features
- Fully wireless SmartCell fire detector
- Dual smoke and heat detection
- Configurable smoke/heat sensitivity
- Individual device addressing
- Bidirectional 868 MHz wireless communication
- Fire indication LED
- Anti-tamper locking mechanism
- Quick and minimally disruptive installation
- Suitable for use with the SmartCell wireless fire alarm system
- Third-party certified
- Designed for professional installation and commissioning
Technical specifications
| Specification |
Detail |
| Model |
SC-21-0200-0001-99 |
| Detection |
Dual smoke & heat |
| Wireless frequency |
868 MHz |
| Communication |
Bidirectional |
| Smoke sensitivity |
Standard / Normal + AVF |
| Heat detection |
58°C or 72°C, static or rate-of-rise depending on configuration |
| Power |
3 × 3.6V lithium thionyl chloride batteries |
| Dimensions |
Approx. 110mm diameter × 61mm deep |
| Protection |
Indoor use |
| Approvals |
EN54-5, EN54-7, EN54-13 and EN54-25 |
| System |
EMS SmartCell |
The SmartCell system allows the detector's smoke and heat settings to be configured at the control panel.
Installation
Professional SmartCell installation required.
This detector must be installed, enrolled and programmed to a SmartCell control panel. Installation should be carried out by a suitably trained and competent person in accordance with the system design and applicable fire safety requirements.
Installation service:
Available through Safe & Smart — see our Professional Installation collection.
What you need
For a new SmartCell installation, you will normally require:
1. SmartCell Wireless Fire Control Panel
2. SmartCell detectors — this product
3. Additional SmartCell devices as required — e.g. call points, sounders or other system devices
4. Professional configuration and commissioning
Please contact us if you're unsure which SmartCell equipment you need.