{"product_id":"ems-smartcell-wireless-fire-alarm-control-panel","title":"SmartCell Wireless Fire Alarm Control Panel","description":"\u003ch2 data-start=\"849\" data-end=\"893\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"852\" data-end=\"893\"\u003eSmartCell Wireless Fire Control Panel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"895\" data-end=\"1231\"\u003eThe \u003cstrong data-start=\"899\" data-end=\"940\"\u003eSmartCell Wireless Fire Control Panel\u003c\/strong\u003e is the central control unit for the SmartCell wireless fire detection system, providing a flexible, professional solution for smaller commercial properties, residential applications and other buildings where a conventional hardwired fire alarm installation may be disruptive or impractical.\u003c\/p\u003e\n\u003cp data-start=\"1233\" data-end=\"1579\"\u003eSmartCell uses robust \u003cstrong data-start=\"1255\" data-end=\"1293\"\u003e868–870 MHz wireless communication\u003c\/strong\u003e, avoiding the extensive cabling normally associated with a conventional fire alarm system. The system provides two-way communication between the control panel and wireless devices, with faults and low-battery conditions reported back to the panel. \u003cspan class=\"contents\" data-content-reference-start=\"1537\" data-content-reference-end=\"1569\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1581\" data-end=\"1984\"\u003eThe system can incorporate SmartCell smoke and heat detectors, sounders, visual alarm devices, manual call points and other wireless devices, allowing a system to be designed around the requirements of the property. SmartCell supports \u003cstrong data-start=\"1816\" data-end=\"1841\"\u003eup to 32 fire devices\u003c\/strong\u003e, with the wider system capable of supporting up to \u003cstrong data-start=\"1893\" data-end=\"1945\"\u003e64 devices when information devices are included\u003c\/strong\u003e. \u003cspan class=\"contents\" data-content-reference-start=\"1937\" data-content-reference-end=\"1970\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"1986\" data-end=\"2032\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1990\" data-end=\"2032\"\u003eDesigned for professional installation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2034\" data-end=\"2269\"\u003eThe SmartCell control panel is \u003cstrong data-start=\"2065\" data-end=\"2097\"\u003enot a standalone smoke alarm\u003c\/strong\u003e. It forms the central component of a complete wireless fire detection system and must be correctly designed, configured and commissioned with compatible SmartCell devices.\u003c\/p\u003e\n\u003cp data-start=\"2271\" data-end=\"2405\"\u003eFor this reason, we recommend purchasing the panel together with professional installation and system design advice from Safe \u0026amp; Smart.\u003c\/p\u003e\n\u003chr data-start=\"2407\" data-end=\"2410\"\u003e\n\u003ch1 data-start=\"2412\" data-end=\"2426\"\u003eKey features\u003c\/h1\u003e\n\u003cul data-start=\"2428\" data-end=\"3145\"\u003e\n\u003cli data-start=\"2428\" data-end=\"2470\"\u003e\u003cstrong data-start=\"2430\" data-end=\"2470\"\u003eFully wireless fire detection system\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"2471\" data-end=\"2507\"\u003eSupports up to \u003cstrong data-start=\"2488\" data-end=\"2507\"\u003e32 fire devices\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2508\" data-end=\"2595\"\u003eUp to \u003cstrong data-start=\"2516\" data-end=\"2564\"\u003e64 devices across the wider SmartCell system\u003c\/strong\u003e, including information devices\u003c\/li\u003e\n\u003cli data-start=\"2596\" data-end=\"2637\"\u003e\u003cstrong data-start=\"2598\" data-end=\"2637\"\u003e16 fire\/information zone indicators\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"2638\" data-end=\"2677\"\u003eCompact surface-mounted control panel\u003c\/li\u003e\n\u003cli data-start=\"2678\" data-end=\"2709\"\u003e\u003cstrong data-start=\"2680\" data-end=\"2709\"\u003e80-character OLED display\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"2710\" data-end=\"2742\"\u003eTwo-way wireless communication\u003c\/li\u003e\n\u003cli data-start=\"2743\" data-end=\"2780\"\u003e\n\u003cstrong data-start=\"2745\" data-end=\"2760\"\u003e868–870 MHz\u003c\/strong\u003e operating frequency\u003c\/li\u003e\n\u003cli data-start=\"2781\" data-end=\"2812\"\u003eIntegrated mains power supply\u003c\/li\u003e\n\u003cli data-start=\"2813\" data-end=\"2841\"\u003e\u003cstrong data-start=\"2815\" data-end=\"2841\"\u003e6V 4Ah standby battery\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-start=\"2842\" data-end=\"2898\"\u003eOptional communications module for remote connectivity\u003c\/li\u003e\n\u003cli data-start=\"2899\" data-end=\"2984\"\u003eSuitable for SmartCell wireless smoke, heat, sounder, beacon and call-point devices\u003c\/li\u003e\n\u003cli data-start=\"2985\" data-end=\"3041\"\u003eDesigned for fast installation with minimal disruption\u003c\/li\u003e\n\u003cli data-start=\"3042\" data-end=\"3145\"\u003eSuitable for small to medium-sized fire detection installations \u003cspan class=\"contents\" data-content-reference-start=\"3094\" data-content-reference-end=\"3126\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3147\" data-end=\"3150\"\u003e\n\u003ch1 data-start=\"3152\" data-end=\"3178\"\u003eTechnical specifications\u003c\/h1\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3180\" data-end=\"4137\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3180\" data-end=\"3232\"\u003e\n\u003ctr data-start=\"3180\" data-end=\"3232\"\u003e\n\u003cth data-start=\"3180\" data-end=\"3196\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3196\" data-end=\"3232\" data-col-size=\"md\" class=\"last:pe-10\"\u003eSmartCell Wireless Control Panel\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3243\" data-end=\"4137\"\u003e\n\u003ctr data-start=\"3243\" data-end=\"3277\"\u003e\n\u003ctd data-start=\"3243\" data-end=\"3255\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3245\" data-end=\"3254\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3255\" data-end=\"3277\" data-col-size=\"md\"\u003eSC-11-1201-0001-99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3278\" data-end=\"3337\"\u003e\n\u003ctd data-start=\"3278\" data-end=\"3296\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3280\" data-end=\"3295\"\u003eSystem type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3296\" data-end=\"3337\" data-col-size=\"md\"\u003eWireless fire detection control panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3338\" data-end=\"3371\"\u003e\n\u003ctd data-start=\"3338\" data-end=\"3365\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3340\" data-end=\"3364\"\u003eMaximum fire devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3365\" data-end=\"3371\"\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3372\" data-end=\"3452\"\u003e\n\u003ctd data-start=\"3372\" data-end=\"3402\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3374\" data-end=\"3401\"\u003eMaximum system capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3402\" data-end=\"3452\" data-col-size=\"md\"\u003eUp to 64 devices including information devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3453\" data-end=\"3481\"\u003e\n\u003ctd data-start=\"3453\" data-end=\"3475\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3455\" data-end=\"3474\"\u003eZone indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3475\" data-end=\"3481\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3482\" data-end=\"3517\"\u003e\n\u003ctd data-start=\"3482\" data-end=\"3496\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3484\" data-end=\"3495\"\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3496\" data-end=\"3517\" data-col-size=\"md\"\u003e80-character OLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3518\" data-end=\"3548\"\u003e\n\u003ctd data-start=\"3518\" data-end=\"3537\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3520\" data-end=\"3536\"\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3537\" data-end=\"3548\" data-col-size=\"md\"\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3549\" data-end=\"3594\"\u003e\n\u003ctd data-start=\"3549\" data-end=\"3573\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3551\" data-end=\"3572\"\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3573\" data-end=\"3594\" data-col-size=\"md\"\u003e220–240V AC, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3595\" data-end=\"3623\"\u003e\n\u003ctd data-start=\"3595\" data-end=\"3615\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3597\" data-end=\"3614\"\u003eRated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3615\" data-end=\"3623\"\u003e0.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3624\" data-end=\"3656\"\u003e\n\u003ctd data-start=\"3624\" data-end=\"3646\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3626\" data-end=\"3645\"\u003eStandby battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3646\" data-end=\"3656\" data-col-size=\"md\"\u003e6V 4Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3657\" data-end=\"3697\"\u003e\n\u003ctd data-start=\"3657\" data-end=\"3682\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3659\" data-end=\"3681\"\u003eWireless frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3682\" data-end=\"3697\"\u003e868–870 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3698\" data-end=\"3742\"\u003e\n\u003ctd data-start=\"3698\" data-end=\"3722\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3700\" data-end=\"3721\"\u003eTransmitter power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3722\" data-end=\"3742\" data-col-size=\"md\"\u003e14dBm max \/ 25mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3743\" data-end=\"3780\"\u003e\n\u003ctd data-start=\"3743\" data-end=\"3760\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3745\" data-end=\"3759\"\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3760\" data-end=\"3780\"\u003e275 × 220 × 80mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3781\" data-end=\"3804\"\u003e\n\u003ctd data-start=\"3781\" data-end=\"3794\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3783\" data-end=\"3793\"\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3794\" data-end=\"3804\" data-col-size=\"md\"\u003e1.55kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3805\" data-end=\"3837\"\u003e\n\u003ctd data-start=\"3805\" data-end=\"3820\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3807\" data-end=\"3819\"\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3820\" data-end=\"3837\" data-col-size=\"md\"\u003eSurface mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3838\" data-end=\"3895\"\u003e\n\u003ctd data-start=\"3838\" data-end=\"3858\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3840\" data-end=\"3857\"\u003eCable entries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3858\" data-end=\"3895\"\u003e4 × 100mm bottom \/ 4 × 100mm rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3896\" data-end=\"3941\"\u003e\n\u003ctd data-start=\"3896\" data-end=\"3924\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3898\" data-end=\"3923\"\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3924\" data-end=\"3941\" data-col-size=\"md\"\u003e-5°C to +45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3942\" data-end=\"3997\"\u003e\n\u003ctd data-start=\"3942\" data-end=\"3974\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3944\" data-end=\"3973\"\u003eMaximum relative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3974\" data-end=\"3997\"\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3998\" data-end=\"4026\"\u003e\n\u003ctd data-start=\"3998\" data-end=\"4016\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4000\" data-end=\"4015\"\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4016\" data-end=\"4026\" data-col-size=\"md\"\u003eIndoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4027\" data-end=\"4051\"\u003e\n\u003ctd data-start=\"4027\" data-end=\"4043\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4029\" data-end=\"4042\"\u003eIP rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4043\" data-end=\"4051\" data-col-size=\"md\"\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4052\" data-end=\"4104\"\u003e\n\u003ctd data-start=\"4052\" data-end=\"4068\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4054\" data-end=\"4067\"\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4068\" data-end=\"4104\" data-col-size=\"md\"\u003eEN54-2, EN54-4, EN54-13, EN54-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4105\" data-end=\"4137\"\u003e\n\u003ctd data-start=\"4105\" data-end=\"4125\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4107\" data-end=\"4124\"\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4125\" data-end=\"4137\" data-col-size=\"md\"\u003eCE \/ CPR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"4139\" data-end=\"4253\"\u003eTechnical specifications are taken from the SmartCell product documentation. \u003cspan class=\"contents\" data-content-reference-start=\"4197\" data-content-reference-end=\"4229\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"4255\" data-end=\"4258\"\u003e\n\u003ch1 data-start=\"4260\" data-end=\"4288\"\u003e🔌 Optional communications\u003c\/h1\u003e\n\u003cp data-start=\"4290\" data-end=\"4435\"\u003eThe SmartCell panel can accommodate an optional communications module, allowing the system to be connected for remote services and alarm routing.\u003c\/p\u003e\n\u003cp data-start=\"4437\" data-end=\"4693\"\u003eSmartCell's remote services can provide features such as remote configuration and system information, while suitable communications equipment can also be used for connection to an Alarm Receiving Centre where required. \u003cspan class=\"contents\" data-content-reference-start=\"4631\" data-content-reference-end=\"4664\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"4695\" data-end=\"4782\"\u003e\u003cstrong data-start=\"4695\" data-end=\"4782\"\u003eCommunications modules are not included with this panel unless specifically stated.\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-start=\"4784\" data-end=\"4787\"\u003e\n\u003ch1 data-start=\"4789\" data-end=\"4816\"\u003eProfessional installation\u003c\/h1\u003e\n\u003ch3 data-start=\"4818\" data-end=\"4877\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4822\" data-end=\"4877\"\u003eSmartCell installation — best estimate £500.00 inc VAT\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"4879\" data-end=\"4953\"\u003eWe offer professional installation and commissioning of SmartCell systems.\u003c\/p\u003e\n\u003cp data-start=\"4955\" data-end=\"5078\"\u003eThe \u003cstrong data-start=\"4959\" data-end=\"5048\"\u003e£500.00 inc VAT installation price is a best estimate for a straightforward installation\u003c\/strong\u003e and is \u003cstrong data-start=\"5056\" data-end=\"5077\"\u003esubject to survey\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"5080\" data-end=\"5123\"\u003eThe final installation cost will depend on:\u003c\/p\u003e\n\u003cul data-start=\"5125\" data-end=\"5360\"\u003e\n\u003cli data-start=\"5125\" data-end=\"5164\"\u003eNumber of detectors and other devices\u003c\/li\u003e\n\u003cli data-start=\"5165\" data-end=\"5191\"\u003eProperty size and layout\u003c\/li\u003e\n\u003cli data-start=\"5192\" data-end=\"5218\"\u003eNumber of zones required\u003c\/li\u003e\n\u003cli data-start=\"5219\" data-end=\"5235\"\u003ePanel location\u003c\/li\u003e\n\u003cli data-start=\"5236\" data-end=\"5263\"\u003eMains supply requirements\u003c\/li\u003e\n\u003cli data-start=\"5264\" data-end=\"5286\"\u003eSystem configuration\u003c\/li\u003e\n\u003cli data-start=\"5287\" data-end=\"5295\"\u003eAccess\u003c\/li\u003e\n\u003cli data-start=\"5296\" data-end=\"5324\"\u003eCommissioning requirements\u003c\/li\u003e\n\u003cli data-start=\"5325\" data-end=\"5360\"\u003eAny additional equipment required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5362\" data-end=\"5445\"\u003e\u003cstrong data-start=\"5362\" data-end=\"5445\"\u003eHardwired electrical work and more complex installations are subject to survey.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5447\" data-end=\"5592\"\u003eIf the survey identifies additional requirements that change the installation price, we'll explain these to you \u003cstrong data-start=\"5559\" data-end=\"5591\"\u003ebefore carrying out the work\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"5594\" data-end=\"5597\"\u003e\n\u003ch1 data-start=\"5599\" data-end=\"5622\"\u003eWhy choose SmartCell?\u003c\/h1\u003e\n\u003cp data-start=\"5624\" data-end=\"5877\"\u003eTraditional wired fire alarm systems can require significant cable installation, disruption and making-good. SmartCell's wireless architecture can significantly simplify installation while providing a professional, standards-based fire detection system.\u003c\/p\u003e\n\u003cp data-start=\"5879\" data-end=\"6205\"\u003eIts wireless communication operates in the \u003cstrong data-start=\"5922\" data-end=\"5942\"\u003e868–870 MHz band\u003c\/strong\u003e and is designed specifically for wireless fire systems rather than relying on ordinary Wi-Fi. SmartCell states that its wireless system is designed to meet the requirements of \u003cstrong data-start=\"6119\" data-end=\"6130\"\u003eEN54-25\u003c\/strong\u003e for wireless fire detection systems. \u003cspan class=\"contents\" data-content-reference-start=\"6139\" data-content-reference-end=\"6158\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"6207\" data-end=\"6210\"\u003e\n\u003ch3 data-start=\"6212\" data-end=\"6229\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6216\" data-end=\"6229\"\u003eImportant\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"6231\" data-end=\"6317\"\u003e\u003cstrong data-start=\"6231\" data-end=\"6317\"\u003eThis product is a control panel and is not a complete fire alarm system by itself.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6319\" data-end=\"6460\"\u003eA suitable system requires compatible SmartCell devices and professional design, configuration and commissioning appropriate to the property.\u003c\/p\u003e\n\u003cp data-start=\"6462\" data-end=\"6575\"\u003eFor advice on designing a SmartCell system for your home or business, \u003cstrong data-start=\"6532\" data-end=\"6574\"\u003econtact Safe \u0026amp; Smart before purchasing\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"6577\" data-end=\"6580\"\u003e","brand":"Safe \u0026 Smart","offers":[{"title":"Supply Only","offer_id":53561444204810,"sku":null,"price":600.0,"currency_code":"GBP","in_stock":true},{"title":"Professional Installation, Certification \u0026 Configuration","offer_id":53561444237578,"sku":null,"price":1100.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0917\/5154\/7146\/files\/SmartCell_Fire_Alarm_Control_Panel.jpg?v=1786731769","url":"https:\/\/safeandsmart.store\/products\/ems-smartcell-wireless-fire-alarm-control-panel","provider":"Safe \u0026 Smart","version":"1.0","type":"link"}